Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. med. vet. zootec ; 68(5): 1168-1176, set.-out. 2016. ilus
Article in English | LILACS, VETINDEX | ID: biblio-827891

ABSTRACT

The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.(AU)


Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.(AU)


Subject(s)
Animals , Rabbits , Biocompatible Materials/analysis , Eye Evisceration/veterinary , Eye, Artificial/veterinary , Polymers , Acrylonitrile/analysis , Butadienes/analysis , Microscopy, Electron, Scanning/veterinary , Nylons
2.
Braz. j. vet. res. anim. sci ; 32(4): 251-5, 1995. ilus
Article in English | LILACS | ID: lil-240110

ABSTRACT

A substituiçäo da córnea em lesöes oculares tem merecido a atençäo dos oftalmologistas, sendo que vários materiais têm sido usados para este fim. O pericárdio de equino, conservado em glicerina, foi usado no reparo de lesöes penetrantes de córnea de dois cäes, um pela excisäo de melanoma límbico, outro pela presença de estafiloma periférico. Cäo, Pastor Alemäo, com 6 anos de idade, apresentando massa de 1 cm de diâmetro, localizada na regiäo temporal do limbo esclero-corneano do olho direito, com 2 meses de evoluçäo e cäo de 4 meses, mestiço, que teve ferida sua córnea esquerda com prolapso de íris, em consequência de arranhadura de gato, 5 dias antes, foram examinados no Serviço de Oftalmologia do Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnica da Universidade de Säo Paulo. As lesöes de ambos os animais foram reparadas com fragmento de pericárdio de equino para fechamento do defeito produzido. Aplicaçäo de pomada antibiótica e colírio de atropina de 1 por cento foi instituída no pós-operatório. A pressäo intra-ocular foi baixa nos primeiros dias subsequentes à cirurgia, mas foi gradativamente aumentando chegando a valores normais. Inicialmente, tecido de granulaçäo foi observado próximo ao implante, e opacificaçäo do pericárdio permaneceu. Colírio de dexametasona foi entäo indicado, sendo que o tecido de granulaçäo desapareceu dois meses após a cirurgia. A câmara anterior permaneceu profunda durante toda a evoluçäo. O acompanhamento pós-operatório mostrou os olhos em boas condiçöes após dezoito meses


Subject(s)
Animals , Dogs/surgery , Cornea/surgery , Eye, Artificial/veterinary , Pericardium
SELECTION OF CITATIONS
SEARCH DETAIL